Electrical installation
B0046191 / Rev. 1.12
66
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
5.2.5.5 CanOpen
An M12 plug with inverse coding is used for the CanOpen connection. A T-connector is not
necessary, because the control unit is equipped with input and output.
The corresponding cable plugs are part of the standard scope of supply.
Note
If the E20 is the last participant in the bus, then an external termination
resistor should be placed into the open connector. The resistor is not
included in the scope of supply.
Allocation of CanOpen connection
Input (Pos. B)
Output (Pos. C)
M12, 5-pin, B-coded, male connector at control unit
M12, 5-pin, B-coded, female connector at control unit
View:
plug side
Pin 1
shield
View:
plug side
Pin 2
n. a.
Pin 3
GND
Pin 4
CAN_H
Pin 5
CAN_H
Suppliers / types / notes: Binder, type 715 (B-coded) and others
5.2.5.6
Interbus-S
The corresponding cable plugs are part of the standard scope of supply.
Allocation of Interbus-S connection
Input (Pos. C2, male connectors)
Output (C1, female connectors)
M12, 5-pin, B-coded,
Male contacts at the control unit (male socket)
M12, 5-pin, B-coded
Female contacts at the control unit (female socket)
View:
plug side
pin 1
DO
View:
plug side
pin 1
DO
pin 2
/DO
pin 2
/DO
pin 3
DI
pin 3
DI
pin 4
/DI
pin 4
/DI
pin 5
GND
pin 5
GND
Plug enclosure
shield
Plug enclosure
shield
The module supports 500 kbit/s operation. The corresponding cable plugs are part of the standard
scope of supply.
5.2.5.7 ProfiNet IO
The ProfiNet IO connection is implemented as 1-Port.
Allocation of ProfiNet IO connection
Round-shape connector, M12, 4-pin., D-coded,
socket contact at control unit (Pos. C2)
View:
Plug side
Pin 1
TD +
Pin 2
RD +
Pin 3
TD –
Pin 4
RD –
Plug enclosure
Shield
The corresponding cable plugs are part of the standard scope of supply.
2
5
1
3
4
5
2
1
3
4
2
5
1
3
4
5
1
2
4
3
1
2
3
4