![Roland R1000 series E20 Скачать руководство пользователя страница 152](http://html1.mh-extra.com/html/roland/r1000-series-e20/r1000-series-e20_manual_1479459152.webp)
Manual
Double Sheet Detector R1000 series E20
with integrated fieldbus interface
Appendix
B0046191 / Rev. 1.12
152
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
Measuring time P42AGS (of old Device-Hardware-Versions 1 – 4)
Fig. 106: System reaction time P42AGS
100
110
120
130
140
150
160
170
180
190
200
210
220
230
240
250
260
270
280
290
300
310
320
330
340
350
360
370
380
390
4,0
Single sheet thickness
(Nominal thickness) [mm]
Standard working range
3,5
3,0
2,5
2,0
1,5
1,0
0,5
0
150%
120%
P42AGS
4 sensors
3 sensors
2 sensors
1 sensor
S
ystem rea
c
ti
on
time
[ms]