![Roland R1000 series E20 Скачать руководство пользователя страница 129](http://html1.mh-extra.com/html/roland/r1000-series-e20/r1000-series-e20_manual_1479459129.webp)
Manual
Double Sheet Detector R1000 series E20
with integrated fieldbus interface
B0046191 / Rev. 1.12
Fault messages, causes and remedies
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
129
9
Fault messages, causes and remedies
Pos: 70 /Doppelblech/Geräte/E20 Bus/9 Fehlermeldungen/Fehlermeldungen, Ursachen und Abhilfen @ 0\mod_1173279804390_501.docx @ 3269 @ 2222222222 @ 1
In case of malfunction a message containing the fault number and the associated error text is
displayed
Fig. 103: Example of a fault message
The fault number indicates the fault and the probable cause. The fault description and the suitable
measures to remedy the fault condition are found in the following tables. The cause of malfunction
must be eliminated before the equipment can continue operation.
The fault can be cleared by pressing the
MENU
key on the control unit.
Note
As long as the cause of the fault is not eliminated, the fault cannot be
cleared.
The fault messages are summarized into the following classes:
• Memory
faults
• Teach-In
faults
•
Transmission faults (RS232)
•
Measuring operating faults
• Keyboard
faults
•
Operating voltage faults
•
PLC input faults
•
Fieldbus operation faults
•
Other faults
Error code: 60
power