Start-up
B0046191 / Rev. 1.12
116
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
System parameter 3:
Selecting the dimensions for output via fieldbus (mm / inch).
Fig. 74: Selecting the dimensions for the fieldbus output
When changing the measurement dimensions, then the sheet metal thicknesses of the stored
program parameters are also converted into the new dimension. As in the previous parameter,
%mm and %inch are also available.
System parameter 4:
not available (reserve).
Fig. 75: Reserved system parameter
System parameter 5:
Setting the bus address.
Abb. 76: Setting the fieldbus address
•
Profibus:
1 - 125
•
ControlNet: 0 - 99
•
DeviceNet:
0 - 63
•
CanOpen:
1 - 127
•
ProfiNet IO: – –
•
CC-Link:
1 – 62
• EtherNet/IP
–
–
• EtherCAT –
–
Note for Profibus:
If this adjustment is to be made in the hardware, then the bus
address can be set with the rotary switches inside the
enclosure (1 to 99). If this adjustment is to be made via
software, then the rotary switches must be turned to
address 0.
This system parameter is only for EtherNET/IP
If DHCP is switched on, the IP-setting will done via
DHCP. If DHCP switched off, must the IP-adress,
SubNET and Gateway be selected.
Fig. 77: Setting DHCP
Here is the IP-address selected.
Fig. 78: Setting IP-address
system parameter 3
bus readout: mm
system parameter 4
not available
system parameter 5
bus address: 1
system parameter 5
EthernetIP DHCP: no
system parameter 5b
IP: 192.168. 0. 10