Manual
Double Sheet Detector R1000 series E20
with integrated fieldbus interface
B0046191 / Rev. 1.12
Communication with the PLC
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
101
6.5.5
Start continuous measurement via external input
Fig. 53: Timing diagram for start continuous measurement via external inputs
Note
The output function result is set with the arrival of the first measured
value and remains set.
t
s
: System reaction time = Measuring time ( see chapter 2.4)
t
p
: additional break times:
•
P30, P42, P42A, P75V
0,5 seconds
•
P36
1,0
second
•
P75
2,0
seconds
•
P128
7,0
seconds
1)
In case of “Function fault“ = 1 “Function result“ will sometimes remain at 0.
Pos: 52 /Doppelblech/Geräte/E20 Bus/6 Kommunikation mit der SPS/Feldbus-Konfigurationsdateien @ 0\mod_1173432978734_501.docx @ 3334 @ 233333333 @ 1
< 5ms
t
s
< 10ms
t
s
p
t
+
t
s
p
t
+
t
s
p
t
+
t
s
p
t
+
IN / BIN
Measurement start
BIN
Sensor selection A/B
BOUT
Sensor selection A/B
BOUT
Function result)
1)
BOUT
Function fault
BOUT
Ready
BOUTBus
(0-sheet, 1-sheet, 2-sheet)
OUT
(0-sheet, 1-sheet, 2-sheet)
„1” if fault
„0” if fault
„0“ active
„0“ active