Manual
Double Sheet Detector R1000 series E20
with integrated fieldbus interface
Mounting
B0046191 / Rev. 1.12
48
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
4.3.2.2 Spring loaded sensor bracket SH75GS
Fig. 22: Spring loaded sensor bracket SH75GS
Pos: 33 /Doppelblech/Sensoren/Sensorhalterungen/Gefederte Sensorhalterung S SHS75GS mit Flachsauger @ 1\mod_1215005515656_501.docx @ 6417 @ 344 @ 1
Sensor
6
6
"A"
54
Hu
b
m
a
x
.
6
5
m
in.
25
9
8
View in direction "A"
without sensor
152.5
15
2.5
20,5
75°
44
.5
x
4
5
°
19
x
4
5°
R
=
66
.7
R
=
42
.5
120°
10.5
4
5
°
movable
10
Ø
fixed
All Dimensions are in mm. Tolerance: ±0.4 mm.