Installation Manual
37
Location: 055 Automatic CS Protocols:
Digit
Format Name
Inter digit Time
Data
Frequency
Remarks
00
(Default)
Pulsed Protocol
01 Contact
ID
NA
NA
-
02
Contact ID -
Domestic
NA NA
No Open/Close reports)
03
SIA (Level 1)
390 ms
1800 Hz
-
04
SIA - Domestic
390 ms
1800 Hz
No Open/Close reports)
05
Ademco 4/2 Express
South Africa
NA NA
Special values for the South
African market.
06
Ademco 4/2 Express
NA
NA
-
Upload/Download Rings: Location 056
Location 056 sets the number of rings that the ORBIT-14 will wait before
automatically answering an incoming call. If such a call was initiated by the alarm
company’s Upload/Download software, a process begins which allows a Remote
Programming session to take place.
Location: 056 Number of Rings
Default: 08
Choose a number of rings greater than that which the customer will normally wait to
answer an incoming call. Enter the number of rings (between 00-15).
NOTE:
If an Answering Machine is in use and so programmed, entries made in this location will be
ignored (see Location 052 / 2
nd
Digit). 00 indicates an immediate connection without any rings.
Swinger Shutdown Limit: Location 057
Location: 057 Swinger Shutdown Limit
Default: 00
A swinger is a repeated violation of the same zone, often resulting in a nuisance
alarm, and usually due to a malfunction, an environmental problem, or the incorrect
installation of a detector or sensor.
This parameter specifies the number of violations of the same zone reported during a
single armed period, before the zone is automatically bypassed.
Range: 00-15 times.
Location: 058 Not Applicable
NOTE:
Enter
00
to disable the swinger shutdown.