Installation Manual
12
Wiring Auxiliary Devices
Use the
Auxiliary Power AUX (+) COM (-)
terminals to power PIRs, glass-break
detectors (4-wire types), smoke detectors, audio switches, photoelectric systems
and/or any device that requires a 12V DC power supply.
NOTES:
The total power from the
AUX
terminals should not exceed 600mA.
To connect a 4-wire smoke detector or devices that require resetting after an alarm condition,
connect the Auxiliary power
AUX
and UO terminals (refer to page 8 for smoke detector wiring).
Remember to define the UO as Switched Auxiliary (refer to page 31).
In addition, when connecting a 4-wire smoke detector observe the wiring guidelines of the local
requirements applicable to smoke detectors.
To prevent a possible drop in voltage due to current requirements and distances involved,
make sure to use the appropriate wire gauge.
If the auxiliary outputs are overloaded (exceed 600mA) and are shut down, you must
disconnect all loads from the outputs for a period of at least 10 seconds before you reconnect
any load to the auxiliary outputs.
Bell Tamper
The bell tamper is a tamper input that is terminated by an EOL resistor (2.21 K
Ω
). If
the line is cut or shorted, the alarm is turned on.
Connect the bell tamper to the BELL TMP and COM terminals on the main panel.
Box Tamper
The box tamper is a tamper input (NC - normally closed) for the metal box, which
protects both sides of the box. This means that if the box is opened or removed from
the wall, the tamper opens and turns on the alarm.
Connect the box tamper to the BOX TMP and COM terminals on the main panel.
NOTE:
For Bell and Box tamper supervision, connect the tamper switches before applying the main
power to the system.