Installation Manual
25
Locations: 017-030 Zone 1-14: (1
st
Digit): Zone Type
2
Day Zone
Usually assigned to an infrequently used door, such as an emergency door or a
movable skylight. Used to alert the system user if a violation occurs during the
disarmed period (trouble by day; burglary at night), as follows:
•
With the system armed (either AWAY or Group), the zone acts as an instant zone.
A violation of this zone after the system is armed or during the Exit Delay time period
causes an immediate intrusion alarm.
•
With the system disarmed, a violation of this zone attempts to alert the user by
causing the POWER LEDs on all keypads to flash rapidly. This directs the user to
view the system's TROUBLE indications.
3
Instant (Intrusion)
Usually intended for non-exit/entry doors, window protection, shock detection, and
motion detectors. Causes an immediate intrusion alarm if violated when the system is
armed or during the Exit Delay time period (Only in IMQ definition).
4
Exit /Entry Delay
If violated, a zone with this designation will not cause an intrusion alarm during the
Entry and Exit Delay periods.
5
Exit (OPEN)/Entry
Such a zone behaves as described above in Entry/Exit Delay, except that if faulted at
the time the system is armed, it will be bypassed and NOT prevents system arming.
To avoid an intrusion alarm, however, the zone must be secured before the expiration
of the Exit Delay period (Location 11).
6
Entry Follower
Usually assigned to motion detectors and to interior doors protecting the area
between the entry door and the keypad.
This zone will cause an immediate intrusion alarm when violated unless an Entry/Exit
zone was violated first. In such a case, an Entry Follower zone(s) will remain
bypassed until the end of the Entry Delay period.
7
Fire Zone
Intended for smoke or other types of fire detectors. If violated, will cause an immediate
fire alarm. A short in the zone wiring will cause a fire alarm. A fault in the wiring to the
zone will cause a Fire Trouble (fire LED blinks). A fire zone cannot be disabled or
bypassed.
8
Panic Zone
Used for external panic buttons and wireless panic transmitters. If violated an
immediate panic alarm will be announced.
9
Pulsed Key-switch Zone - Instant
If desired an external SPST spring - loaded, normally open, momentary type key
switch can be added for system arming and disarming. The key switch permits an
instant arm and disarming of the system after tripping.
A
Pulsed Key-switch Zone - Delayed
This zone behaves similar to the
Pulsed Key-switch Zone - Instant
, described
above, except that an exit delay will follow the arming of the system.
B
Latch-Key-switch Zone – Instant:
If desired for system arming/disarming, connect
an external SPST latching type (non-momentary) key-switch to any zone terminals,
given this designation.