Installation Manual
16
Installer Programming
The Keypad
The ORBIT-14 can support up to five keypads, with a choice of four styles (LCD, 6-
LED, 8-LED and 14-LED types), from which virtually all features may be accessed. In
addition to the functions it provides for the user, each of the keypads can be used by
an installer to program the system parameters.
An attempt to enter an incorrect series of keystrokes will result in three error beeps.
All program location values (data) are displayed by zone indicators on the keypad’s
LEDs.
Restoring Factory Defaults to the ORBIT-14
1. Your
ORBIT-14
and at least one LED Keypad should already be wired together
and/or physically installed.
2. Remove all power from the Printed Circuit.
3. Place
the
ORBIT-14
’s J1 (DEFAULT) jumper over both corresponding pins.
(Refer to page 8).
4. Reapply power (AC and/or Standby Battery) to the PC Board.
5. After a short beep is heard, remove the J1 jumper. The
ORBIT-14
’s default
settings are now restored.
6. Check that the POWER LED is flashing. Depending on the state of the system,
the READY LED and the Zone LEDs may or may not be lit.
Introduction to Programming
First, check that the panel’s J1 (DEFAULT) jumper is NOT covering both pins on the
PC Board.
The ORBIT-14 stores information in 168 programming locations. The data stored in
any location is represented by numbers and/or letters. Some locations require just
one digit, while most require two. Others may require several more digits (e.g. those
used to store phone numbers and account numbers).
It is not necessary to enter data into all categories. Many locations have been factory-
programmed with default parameters.
NOTE:
Power can be removed from the ORBIT-14, as its memory does not require a source of power
to retain its information.