User Manual
- 3.22 -
PCS 200 Kit
After setting a desired number of turns, the system will start up the motor related to
the fertilizer 1 or the microgranulator 1. This operation can be done by measuring the
spread quantity, dividing it by the number of turns and, if different from 1kg/dm³, even
by the density, i.e:
Volume per turn =1000 x Measured quantity / (Density * turns) [cm³/turn]
Tramline
Tab
This page allows to manage the advanced function called
“
Tramline
”
, i.e. the
automatic row exclusion function.
The manual function is already available in the HOME page by using the buttons you
can find under the column of each seeding row.