Installation
- 2.10 -
PCS 200 Kit
2.8
MACHINE POSITION SENSOR
It is a mechanical proximity sensor (P/N ROJ 05R01422) used to define whether the
machine is in seeding position (machine lowered) or in transfer position (machine
lifted).
Figure 2-10
–
Position sensor
The sensor must be fastened to the machine frame, in such a way that:
•
in seeding position, when the machine is lowered, the sensor is deactivated
(the rod is in rest position)
•
in transfer position, i.e. when the machine is lifted, the sensor is activated
The sensor must be connected to the ECU cabling connector indicated by PROXY-
MACHINE.
The following procedure can be applied if you want to control the proper operation
while checking the machine overall operation.
Содержание PCS 200
Страница 1: ...PCS 200 Installation Operation Maintenance ORIGINAL INSTRUCTIONS ...
Страница 4: ......
Страница 33: ...Installation PCS 200 Kit 2 13 Figure 2 Wiring diagram of the system without alternator ...
Страница 35: ...Installation PCS 200 Kit 2 15 Figure 2 14 ECU wiring diagram ...
Страница 41: ...Installation PCS 200 Kit 2 21 This page is intentionally left blank ...
Страница 102: ...User Manual PCS 200 Kit 3 61 This page is intentionally left blank ...
Страница 105: ...Maintenance and Troubleshooting PCS 200 Kit 4 3 4 4 SPARE PARTS ...
Страница 111: ...Maintenance and Troubleshooting PCS 200 Kit 4 9 This page is intentionally left blank ...