Maintenance and Troubleshooting
PCS 200 Kit
- 4.7 -
Exchanging the faulty motor with another properly functioning motor already
mounted on the machine
If no spare MD is available, you can decide to exchange the faulty MD with another
motor mounted on the machine, in order to continue working (you can for ex.
exchange a faulty motor related to the seeding disc with the motor related to the
micro-granulator, in case this last function is not needed).
Warning!
: The following procedure requires that the motor having a failure is still
able to communicate via the CAN line. In case a 1-1801
“
Invalid configuration or MD
address
” alarm
is displayed when turning the machine on, even if the configuration
has been changed, you need to follow the procedure:
Removing the MD from the
machine configuration.
1.
Disconnect the system from the power supply via the battery disconnect
switch
2.
Disconnect the faulty MD cables from the MD to be exchanged, using a ¼
”
wrench.
3.
Remove the screws which fix the two motors and extract them from the
seeding disc shaft or the distributor shaft.
4.
Exchange their position, fix the motor in the new position and reconnect the
cables.
5.
Power up the system via the battery disconnect switch
6.
Make sure that no seeding job is active (in that case press STOP).
7.
Press the
“
MD addressing
”
button in the
“
Configuration
”
window to confirm.
8.
Press the
“
Addressing
”
button: all devices have been addressed.
9.
Press the faulty device icon and select
“
Unaddress MD
”
10.
Press the icon of the exchanged motor and select
“
Unaddress MD
”
11.
The icon corresponding to one of the exchanged MDs starts flashing
indicating that it has to be addressed.
12.
Close the MD safety switch on the correct position to address the device.
13.
The icon corresponding to the other MD starts flashing indicating that it has
to be addressed.
14.
Close the MD safety switch on the correct position to address the device.
15.
Once the addressing has been completed, press the
“
Exit
”
button.
Содержание PCS 200
Страница 1: ...PCS 200 Installation Operation Maintenance ORIGINAL INSTRUCTIONS ...
Страница 4: ......
Страница 33: ...Installation PCS 200 Kit 2 13 Figure 2 Wiring diagram of the system without alternator ...
Страница 35: ...Installation PCS 200 Kit 2 15 Figure 2 14 ECU wiring diagram ...
Страница 41: ...Installation PCS 200 Kit 2 21 This page is intentionally left blank ...
Страница 102: ...User Manual PCS 200 Kit 3 61 This page is intentionally left blank ...
Страница 105: ...Maintenance and Troubleshooting PCS 200 Kit 4 3 4 4 SPARE PARTS ...
Страница 111: ...Maintenance and Troubleshooting PCS 200 Kit 4 9 This page is intentionally left blank ...