It allows to calculate the volume cm³ of the auger/distributor
in use.
“
Density
”
measurement
Press the
5
button in the fertilizer and microgranulator configuration page to
calculate by experimentation the density of the product in use.
When pressing the button for the first time, the following screen is displayed:
It is possible to select the motor to be calibrated as well as the prefill speed to be
used.
After pressing the prefill button (for at least 3 complete turns of the auger), it will be
possible to start the density measurement. The following screen is displayed