Functional description of PRxx1 series controllers Rev.H.doc
2016-10-28
42/43
[93][NK] - Delete the Function Card with NK number (NK=00-31)
The command is used for removing Function Card with NK number from the access system, see
[93][*] - Delete all Function Cards
The command is used for removing all Function Cards from the access system, see 2.11 Function
[94][BK] - Adjust keypad backlight (only PR311SE controller)
[BK] = 0 0%
[BK] = 1 20%
[BK] = 2 40%
[BK] = 3 60%
[BK] = 4 80%
[BK] = 5 100%
[95][BK] - Adjust volume level (except for PR411DR controller)
[BK] = 0 0%
[BK] = 1 20%
[BK] = 2 40%
[BK] = 3 60%
[BK] = 4 80%
[BK] = 5 100%
[96][F] - Option: Constant activation of Output1 (REL1) by card in vicinity of reader
Enter [F]=0 to disable the option or enter [F]=1 to enable the option. Default value: <F=0>. See
also 2.7.13 Option: Constant activation of Output 1 by card in vicinity of reader
[97][SS] – Program the timer of
CARD PRESENT
–
SWITCH OFF DELAY
flag in seconds (SS=01-
99)
Do not enter [SS]=00, 01 or 02. By default the timer is off. See also 2.7.9 System Flags.
[97][*][MM] – Program the timer of
CARD PRESENT
–
SWITCH OFF DELAY
flag in minutes
(MM=01-99)
Do not enter [MM]=00. By default the timer is off.
[97][*][*] – Disable
CARD PRESENT
–
SWITCH OFF DELAY
timer
Disable
CARD PRESENT
–
SWITCH OFF DELAY
timer
3.4 Acoustic and visible signals
3.4.1 Visible signals
In PRxx1 series controllers visible signals are presented by means of LED indicators mounted at
controllers enclosures.
Table 13. LED indicators
Name
Color
Function
LED STATUS
Two colors: red or
green
RED corresponds to Armed Mode (see 2.6 Armed and
GREEN corresponds to Disarmed Mode.
LED OPEN
Green
The LED is continuously on when the access is
granted and blinks if the controller awaits for
logging.