Functional description of PRxx1 series controllers Rev.H.doc
2016-10-28
21/43
periodically
every 2 s.
FORCED
ENTRY
Started upon detection of unauthorized door opening or
PIN under duress input (see Facility Code (also called:
Site Code) is a part of the whole proximity card code
which is located between 16th and 24th bit and is
intended to characterize some group of cards
customized and produced for individual order.
Example: If the card has following code
Proximity cards and key fobs provided by Roger
24 bits of the full card code. This reduced code is
presented as three decimal digits (from range
000-255) separated by comma from remaining 5
digits e.g. 238,08887. As a result the first 3
decimal digits before comma correspond to card
Facility Code.
When Facility Code option is active, controller
grants the access to all users with the same
Facility Code. Thanks to this feature controller
2.7.7 Option: Disable PIN under duress).
High
Single 1 sec.
pulses
repeated
periodically
every 1
second.
2.7.11 Option: Enable Door Alarm signaling on internal buzzer
When the option is active, any of following alarm states:
PREALARM
,
DOOR AJAR
and
FORCED ENTRY
is
signaled by internal buzzer.
PREALARM
is started after five consecutive entries of incorrect identifier (card/PIN) within five
minutes.
PREALARM
can be signaled at following outputs:
[01]: Prealarm, [03]: Pr
Door Ajar, [05]: Pr Forced Entry or [07] Pr Door Ajar +
Forced Entry
.
The option is not available in PR411DR as it does not contain buzzer.
2.7.12 Option: Device temporary blocked after 5 wrong logins
When the option is active and
PREALARM
is started then entering of cards and/or PINs at that
controller is blocked for 5 minutes.