Functional description of PRxx1 series controllers Rev.H.doc
2016-10-28
41/43
[86] [*][MM] – Program the timer of
DURESS
flag in minutes (MM=01-99)
Do not enter [MM]=00. Default value: <MM=03>.
[87][SS] – Program the timer of
TROUBLE
flag in seconds (SS = 00-99)
Do not enter [SS]=00. See also 2.7.9 System Flags. Default value: <MM=03>.
[87][*][MM] – Program the timer of
TROUBLE
flag in minutes (MM=01-99)
Do not enter [MM]=00. Default value: <MM=03>.
[88][SS] – Program the timer of
ENTRY DELAY
flag in seconds (SS = 00-99)
Do not enter [SS]=00. See also 2.7.9 System Flags. Default value: <SS=60>.
[88][*][MM] – Program the timer of
ENTRY DELAY
flag in minutes (MM=01-99)
Do not enter [MM]=00. Default value: <SS=60>.
[89] [SS] – Program the timer of
EXIT DELAY
flag in seconds (SS = 00-99)
Do not enter [SS]=00. See also 2.7.9 System Flags. Default value: <SS=60>.
[89] [*] [MM] – Program the timer of
EXIT DELAY
flag in minutes (MM=01-99)
Do not enter [MM]=00. Default value: <SS=60>.
[89] [*] [*] – Disable
ENTRY DELAY
timer
Disable timer of
ENTRY DELAY
flag.
[90] [*] - Disable Facility Code
The command disables Facility Code, see 2.7.6 Facility Code.
[90] [WCN][ABCDEFGH] - Program the Facility Code
[WCD] parameter specifies Facility Code in range of 000-255 (always three digits). [ABCDEFGH]
parameter specifies User Options for all users with Facility Code cards. See also 2.7.6 Facility Code
and 2.3.2 User Options. [ABCDEFGH] parameter:
A=1
Access completely disabled
B=1
Authorization for F1 key at Terminal ID0
C=1
Authorization for F2 key at Terminal ID0
D=1
Authorization for F1 key at Terminal ID1
E=1
Authorization for F2 key at Terminal ID1
F=1
Authorization for User Commands
G=1
Authorization for arming/disarming
H=1
Authorization for Function Cards
[91] [C] - Set the option: Access disabled when controller armed
Enter [C]=0 to disable the option or [C]=1 to enable the option. Default value <F=0>. See 2.7.3
Option: Access Disabled when Controller Armed
[92][NK][FN][A]<Card> - Program the Function Card
[NK] parameter specifies the number of Function Card in range of 00-31. [FN] parameter specifies
the function of Function Card (see 2.11 Function Cards). Enter [A]=0 to disable necessity for
authorization of particular Function Card or enter [A]=1 to enable necessity for authorization of
particular Function Card.
[93]<card> - Delete the Function Card
The command is used for removing particular Function Card from the access system, see 2.11
Function Cards.