Functional description of PRxx1 series controllers Rev.H.doc
2016-10-28
35/43
[17#] <AUTH> (SK) [NNN][P] - Deactivate User Option [P] for the user with ID=NNN
See command [16] above.
[18#] <AUTH> (SK) [P] - Deactivate User Option [P] for all users
See command [16] above.
[20#] <AUTH> (SK) [20] - Delete all Guest users
The command erases all cards and PINS for all Guest users (see 2.3.1 Standard and Guest Users).
[21#] <AUTH> (SK) [G] <Card> - Program the card for the Guest user with ID=[G]
[G] parameter must be in range 0-7 as it corresponds to Guest ID in range of 4000 – 4007 (see
2.3.1 Standard and Guest Users).
[22#] <AUTH> (SK) [G]<PIN> - Program the PIN for Guest user with ID=[G]
[G] parameter must be in range 0-7 as it corresponds to Guest ID in range of 4000 – 4007 (see
2.3.1 Standard and Guest Users).
[23#] <AUTH> (SK) [G] - Delete Guest user with ID=[G]
[G] parameter must be in range 0-7 as it corresponds to Guest ID in range of 4000 – 4007 (see
2.3.1 Standard and Guest Users).
[31#] <AUTH> (SK) [F] - Define AUX1 flag
Enter: [F] = [0] to clear the flag, [F] = [1] to set the flag or [F] = [2] to toggle the flag to opposite
state (see 2.7.9 System Flags)
[32#] <AUTH> (SK) [F] - Define AUX2 flag
Enter: [F] = [0] to clear the flag, [F] = [1] to set the flag or [F] = [2] to toggle the flag to opposite
state (see 2.7.9 System Flags).
[33#] <AUTH> (SK) [F] - Define LIGHT flag
Enter: [F] = [0] to clear the flag, [F] = [1] to set the flag or [F] = [2] to toggle the flag to opposite
state (see 2.7.9 System Flags).
[34#] <AUTH> (SK) [T] - Define Door Mode
Following values of [T] parameter are available (see also 2.5 Door Modes):
[T] = [0] Normal Door Mode
[T] = [1] Unlocked Door Mode
[T] = [2] Cond. Unlocked Door Mode
[T] = [3] Locked Door Mode
[35#] <AUTH> (SK) [A] - Define Identification Mode
Enter: [A] = [0] to set Card or PIN, [A] = [1] to set Card Only, [A] = [2] to set PIN Only, [A] = [3]
to set Card and PIN. See also 2.4 Identification Modes.
Note: After setting PIN Only Identification Mode, MASTER card cannot be used. Similarly after
setting Card Only Identification Mode, MASTER PIN cannot be used.
[39#] <AUTH>
-
Set INTRUDER flag
The command is used for activation of
INTRUDER
flag (see 2.7.9 System Flags).
3.3 Installer Programming Mode
The mode enables detailed configuration of the controller in order to adapt it to specific
requirements at site. This is the manual programming (keypad), opposite to remote programming
by means of PR Master software. Installer Programming can be started both in Armed and
Disarmed Modes (see 2.6 Armed and Disarmed Modes) by means of following command: