Functional description of PRxx1 series controllers Rev.H.doc
2016-10-28
40/43
[77][new INSTALLER card] –Program the new INSTALLER card
The old INSTALLER card is deleted and new one is recorded. By default INSTALLER card is not
defined in the controller at all and MASTER card takes it role. Still, the command [77] can be used
for programming the new INSTALLER card.
[78][new INSTALLER PIN][#] – Program the new INSTALLER PIN
The old INSTALLER PIN is deleted and new one is recorded. By default INSTALLER PIN is not
defined in the controller at all. Still, the Command can be used for programming the new
INSTALLER PIN.
[79][APB] – Program the Anti-passback mode
Enter: [APB] = [0] to disable APB
Enter: [APB] = [1] to enable Soft APB
Enter: [APB] = [2] to enable Hard APB
Default value: <APB=0>
[80][TA] – Set the option: True APB
Enter [TA]=0 to disable the option or enter [TA]=1 to enable the option. See also 2.7.14 Anti-
passback (APB).
[81][SS] – Program the timer of
AUX
1 flag in seconds (SS = 00-99)
Enter [SS]=00 to disable the timer and set flag in latch mode. See also 2.7.4 Option: Door Lock
Controlled in Latch Mode (toggle) and 2.7.9 System Flags. Default value: <SS=00>.
[81][*][MM] – Program the timer of
AUX
1 flag in minutes (MM=01-99)
Do not enter [MM]=00. Default value: <SS=00>.
[82][SS] – Program the timer of
AUX
2 flag in seconds (SS = 00-99)
Enter [SS]=00 to disable the timer and set flag in latch mode. See also 2.7.4 Option: Door Lock
Controlled in Latch Mode (toggle) and 2.7.9 System Flags. Default value: <SS=00>.
[82] [*][MM] – Program the timer of
AUX
2 flag in minutes (MM=01-99)
Do not enter [MM]=00. Default value: <SS=00>.
[83][SS] – Program the timer of
LIGHT
flag in seconds (SS = 00-99)
Enter [SS]=00 to disable the timer and set flag in latch mode. See also 2.7.4 Option: Door Lock
Controlled in Latch Mode (toggle) and 2.7.9 System Flags. Default value: <SS=00>.
[83] [*][MM] – Program the timer of
LIGHT
flag in minutes (MM=01-99)
Do not enter [MM]=00. Default value: <SS=00>.
[84][SS] – Program the timer of
TAMPER
flag in seconds (SS = 00-99)
Do not enter [SS]=00. See also 2.7.9 System Flags. Default value: <MM=03>.
[84] [*][MM] – Program the timer of
TAMPER
flag in minutes (MM=01-99)
Do not enter [MM]=00. Default value: <MM=03>.
[85][SS] – Program the timer of
INTRUDER
flag in seconds (SS = 00-99)
Do not enter [SS]=00. See also 2.7.9 System Flags. Default value: <MM=03>.
[85] [*][MM] – Program the timer of
INTRUDER
flag in minutes (MM=01-99)
Do not enter [MM]=00. Default value: <MM=03>.
[86][SS] – Program the timer of
DURESS
flag in seconds (SS = 00-99)
Do not enter [SS]=00. See 2.7.9 System Flags. Default value: <MM=03>.