![Rockwell Automation PowerFlex 750-Series Скачать руководство пользователя страница 39](http://html.mh-extra.com/html/rockwell-automation/powerflex-750-series/powerflex-750-series_user-manual_1475453039.webp)
Configuring the I/O
4-3
PowerFlex 750-Series Drive DeviceNet Option Module User Manual
Publication 750COM-UM002A-EN-P
1. Start RSLogix 5000. The RSLogix 5000 window appears. Select
File > New to display the New Controller screen (
).
Figure 4.3
New Controller Screen (RSLogix 5000 v16 shown)
Select the appropriate choices for the fields in the screen to match
your application. Then click OK. The RSLogix 5000 window
reappears with the treeview in the left pane.
2. In the treeview, right-click the I/O Configuration folder and select
New Module… The Select Module screen appears. Expand the
Communications group to display all of the available
communication modules (
).
Figure 4.4
Scanner Select Module Screen
3. In the list, select the DeviceNet scanner used by your controller. In
this example, we use a 1756-DNB DeviceNet Scanner, so the
1756-DNB is selected. Then click OK. In the Select Major
Revision pop-up dialog box, select the major revision of its
firmware.
4. Click OK. The scanner’s New Module screen (
Содержание PowerFlex 750-Series
Страница 136: ...G 8 Glossary PowerFlex 750 Series Drive DeviceNet Option Module User Manual Publication 750COM UM002A EN P Notes ...
Страница 141: ...Index 5 PowerFlex 750 Series Drive DeviceNet Option Module User Manual Publication 750COM UM002A EN P Notes ...
Страница 142: ...Index 6 PowerFlex 750 Series Drive DeviceNet Option Module User Manual Publication 750COM UM002A EN P Notes ...
Страница 143: ......