Parameter Descriptions
3-129
Provides status of the profile/indexer. Bits 0-4 are a binary value.
Number of units traveled from the home position.
700
Profile Status
Range:
See figure 3.42
Default:
Read Only
Access:
2
Path:
Pos/Spd Profile>ProfSetup/Status
See also:
Figure 3.42 – Pos/Spd Prof Sts
0
0
0
0
0
x
x
x
0
0
0
0
0
0
0
0
10
0
1
2
3
4
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
Step 1
Step 2
Step 3
Step 4
Step 5
Step 6
Step 7
Step 8
Step 9
Step 10
Step 11
Step 12
Step 13
Step 14
Step 15
Step 16
0
1
1
0
0
1
1
0
0
1
1
0
0
1
1
0
0
0
0
1
1
1
1
0
0
0
0
1
1
1
1
0
0
0
0
0
0
0
0
1
1
1
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
5
6
7
8
9
11
12
13
14
15
1
=Enabled
0
=Disabled
x =Reserved
Bit #
Step
Current Pr
ofile
Pr
of Enab
led
Running
Holding
Homing
At P
osition
At Home
Complete
Vel Override
701
Units Traveled
Range:
-/+ 214748352.00 [0.01]
Default:
Read Only
Access:
2
Path:
Pos/Spd Profile>ProfSetup/Status
See also:
Содержание CNMD180W0ENNNC1
Страница 1: ...Instruction Manual Reach Drive User Manual Manufactured for DBT D2 3561 ...
Страница 206: ...B 4 DBT Reach Drive Manual ...
Страница 238: ...Appendix D 24 DBT Reach Drive User Manual ...
Страница 247: ......