![Rockwell Automation CNMD180W0ENNNC1 Скачать руководство пользователя страница 148](http://html.mh-extra.com/html/rockwell-automation/cnmd180w0ennnc1/cnmd180w0ennnc1_user-manual_1475500148.webp)
3-122
DBT Reach Drive User Manual
Displays the maximum torque on the polished rod in a PCP oil well application.
Minimum speed for the polished rod in a PCP oil well application. Parameter related to
motor minimum speed through total gear ratio.
Maximum speed for the polished rod in a PCP oil well application. Parameter related
to motor minimum speed through total gear ratio.
Selects the type of oil well application.
0 = Disable:
Disconnects binding of oil well parameters.
1 = Pump Jack:
Sets parameters and bindings based on Pump Jack type oil well
2 = PC Oil Well:
Sets parameters and bindings based Progressive Cavity type Pumps
638
Max Rod Torque
Range:
0.0 to 3000.0 ft/lb [0.1 ft/lb]
Default:
500.0 ft/lb
Access:
2
Path:
Applications>Oil Well Pump
See also:
639
Min Rod Speed
Range:
0.0 to 199.0 RPM [0.1 RPM]
Default:
0.0 RPM
Access:
2
Path:
Applications>Oil Well Pump
See also:
640
Max Rod Speed
Range:
200.0 to 600.0 RPM [0.1 RPM]
Default:
300.0 RPM
Access:
2
Path:
Applications>Oil Well Pump
See also:
641
OilWell Pump Sel
Range:
0 = Disable
1 = Pump Jack
2 = PC Oil Well
Default:
0 = Disable
Access:
2
Path:
Applications>Oil Well Pump
See also: