3-120
DBT Reach Drive User Manual
Displays the status bits for Torque Proving.
Displays the load side torque.
Sets the level at which the Torque Alarm becomes active.
Sets the drive action when the Torque Alarm is exceeded.
612
Torq Prove Sts
Range:
See figure 3.41
Default:
Read Only
Access:
2
Path:
Applications>Torque Proving
See also:
Figure 3.41 – Torq Prove Sts
0
0
0
x
0
0
0
0
x
x
x
x
x
x
x
x
10
0
1
2
3
4
5
6
7
8
9
11
12
13
14
15
1
=Enabled
0
=Disabled
x =Reserved
Bit #
EndLimitActv
DecelLimActv
Micr
oP
osActv
BrkSlipAlarm
Brake Set
LoadT
estActv
RefLoadLimtd
631
Rod Load Torque
Range:
0.00 to 32000.00 ft-lb [0.01 ft-lb]
Default:
Read Only
Access:
2
Path:
Applications>Oil Well Pump
See also:
632
TorqAlarm Level
Range:
0.00 to 5000.00 ft-lb [0.01 ft-lb]
Default:
0.00 ft-lb
Access:
2
Path:
Applications>Oil Well Pump
See also:
633
TorqAlarm Action
Range:
0 = No Action
1 = Goto Preset 1
Default:
0 = No Action
Access:
2
Path:
Applications>Oil Well Pump
See also: