Parameter Descriptions
3-143
Adjusts the output voltage to maintain stable motor operation. An increase in the value
increases the output voltage adjustment.
The Stability Filter coefficient is used to adjust bandwidth of a low pass filter. The
smaller the value of this coefficient, the lower the bandwidth of the filter.
This proportional gain adjusts the output voltage at very low frequency in response to
the reactive, or d-axis, motor current. A larger value increases the output voltage
change.
The proportional gain adjusts the output voltage at very low frequency in response to
the active, or q-axis, motor current. A larger value increases the output voltage
change.
507
Volt Stblty Gain
Range:
0 to 32767 [1]
Default:
93
Access:
2
Path:
Utility>Diag-Motor Cntl
See also:
508
Stability Filter
Range:
0 to 32767 [1]
Default:
3250
Access:
2
Path:
Utility>Diag-Motor Cntl
See also:
509
Low Freq Reg Kpld
Range:
0 to 32767 [1]
Default:
64
Access:
2
Path:
Utility>Diag-Motor Cntl
See also:
510
Low Freq Reg Kplq
Range:
0 to 32767 [1]
Default:
64
Access:
2
Path:
Utility>Diag-Motor Cntl
See also: