82
Rockwell Automation Publication 2094-UM001D-EN-P - May 2010
Chapter 5
Connecting the Kinetix 6000 Drive System
DC Common Bus
Configurations
When the IAM module is used in a DC common-bus configuration, the IAM
module is known as a leader IAM or follower IAM module. The IAM
(non-common bus) and leader IAM module have identical three-phase input
power connections. The leader IAM module is responsible for discharging the
DC bus, and for providing common-bus follower drives with DC bus pre-charge,
bus regulation, phase-loss detection, and ground fault detection. Follower IAM
modules do not have three-phase input power connections, but have DC bus
connections from a leader IAM module.
Table 46 - IAM Module Terminology and Use
The Kinetix 6000 leader IAM module can operate with non-Kinetix 6000
follower drives, as can the Kinetix 6000 follower IAM module operate with
non-Kinetix 6000 common-bus leader drives. However, non-Kinetix 6000 leader
and follower drives must meet the same functional requirements as the Kinetix
6000 leader and follower IAM modules.
Figure 40 - Typical DC Common-bus Configuration
This Module
Is Wired
And is
IAM
With three-phase input power.
Not wired in Common-bus mode.
Leader IAM
With three-phase input power, but has DC
common-bus connections to a follower IAM module.
Wired in Common-bus mode.
Follower IAM
Without three-phase input power, but has DC
common-bus connections from a leader IAM module.
Wired in Common-bus mode and
configured by using RSLogix 5000
software.
IMPORTANT
Use Kinetix 6000 drive firmware revision 1.85 and RSLogix 5000 software
version 15 or later, for common-bus power configurations.
IMPORTANT
Any non-Kinetix 6000 common-bus leader IAM module that does not
provide pre-charge is required to add an additional external pre-charge
circuit before connecting to any Kinetix 6000 common-bus follower IAM
module.
DC-
DC+
L3
L2
L1
CONT EN-
CONT EN+
W
V
U
MBRK -
MBRK +
COM
PWR
DBRK -
DBRK +
CTRL 2
CTRL 1
1 2 3 4
1 2 3 4 5 6
1 2
1 2 3 4 5 6
1 2
W
V
U
MBRK -
MBRK +
COM
PWR
DBRK -
DBRK +
1 2 3 4
1 2 3 4 5 6
W
V
U
MBRK -
MBRK +
COM
PWR
DBRK -
DBRK +
1 2 3 4
1 2 3 4 5 6
DC-
DC+
L3
L2
L1
CONT EN-
CONT EN+
W
V
U
MBRK -
MBRK +
COM
PWR
DBRK -
DBRK +
CTRL 2
CTRL 1
1 2 3 4
1 2 3 4 5 6
1 2
1 2 3 4 5 6
1 2
W
V
U
MBRK -
MBRK +
COM
PWR
DBRK -
DBRK +
1 2 3 4
1 2 3 4 5 6
W
V
U
MBRK -
MBRK +
COM
PWR
DBRK -
DBRK +
1 2 3 4
1 2 3 4 5 6
N.C.
N.C.
N.C.
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
BAUD
RATE
TX
RX
DPI
BAUD
RATE
TX
RX
BAUD
RATE
TX
RX
BAUD
RATE
TX
RX
DPI
BAUD
RATE
TX
RX
BAUD
RATE
TX
RX
2094-
x
C
xx
-M
xx-x
Common-bus Leader
IAM Module
2094-
x
M
xx-x
AM Modules
Bonded Cabinet
Ground
Three-phase
Input Power
Kinetix 6000
DC Common Bus
Connections
2094-
x
C
xx
-M
xx-x
Common-bus Follower
IAM Module
2094-
x
M
xx-x
AM Modules
Содержание Allen-Bradley 2094-BC01-M01-S
Страница 4: ...4 Rockwell Automation Publication 2094 UM001D EN P May 2010 Summary of Changes Notes...
Страница 10: ...10 Rockwell Automation Publication 2094 UM001D EN P May 2010 Table of Contents Notes...
Страница 126: ...126 Rockwell Automation Publication 2094 UM001D EN P May 2010 Chapter 5 Connecting the Kinetix 6000 Drive System Notes...
Страница 228: ...228 Rockwell Automation Publication 2094 UM001D EN P May 2010 Appendix B Interconnect Diagrams Notes...
Страница 270: ...270 Rockwell Automation Publication 2094 UM001D EN P May 2010 Appendix F RBM Module Interconnect Diagrams Notes...
Страница 278: ...278 Rockwell Automation Publication 2094 UM001D EN P May 2010 Index Notes...
Страница 279: ......