184
Rockwell Automation Publication 2094-UM001D-EN-P - May 2010
Appendix A
Specifications and Dimensions
Shunt Module Power Specifications
The 2094-BSP2 shunt module is compatible with all 230V and 460V IAM and
AM modules.
Table 101 - 2094-BSP2 Shunt Module Specifications
For External Shunt Module Specifications, refer to
.
Use this table to understand the 230V system shunt specifications for the IAM
module internal shunt resistors, the 2094-BSP2 shunt module, and the Bulletin
1394 passive external shunt modules.
Table 102 - Shunt Module (230V) System Specifications
Shunt Module
Cat. No.
Drive
Voltage
V AC
Resistance
Ω
Peak
Power
kW
Peak
Current
A
Continuous
Power
W
Capacitance
μ
F
Short Circuit
Current Rating
A
Fuse
Replacement
2094-BSP2
230
28.75
5.7
14
200
470
200,000
symmetrical
N/A
(no internal fuse)
460
22.5
28
IAM
Module
2094-
Number of
Axis Modules
Qty
Shunt Module
Cat. No.
Shunt Module Specifications
External Passive
Shunt Module
(1)
Cat. No.
System
Continuous
Shunt Power
W
Resistance
Ω
Peak
Current
A
Peak
Power
kW
Continuous
Power
W
AC05-MP5-
x
0 to 7
N/A
(2)
–
–
–
–
N/A
(2)
0
AC05-M01-
x
–
–
–
–
0
AC09-M02-
x
–
–
–
–
50
(3)
AC16-M03-
x
–
–
–
–
200 plus
(4)
AC32-M05-
x
–
–
–
–
AC
xx
-M
xx
-
x
0 to 6
2094-BSP2
28.75
14.1
5.7
200
N/A
(2)
200 plus
(5)
AC
xx
-M
xx
-
x
0 to 6
2094-BSP2
4
101.3
41
300
1394-SR9A
300
(6)
AC
xx
-M
xx
-
x
900
1394-SR9AF
900
(6)
AC
xx
-M
xx
-
x
1800
1394-SR36A
1800
(6)
AC
xx
-M
xx
-
x
3600
1394-SR36AF
3600
(6)
(1) Refer to
External Shunt Module Specifications
.
(2) Module not part of system configuration.
(3) 50 or the sum of the AM module internal shunt ratings.
(4) 200 plus the sum of the AM module internal shunt ratings.
(5) 200 plus the sum of the IAM module (2094-AC16-M03-
x
and 2094-AC32-M05-
x
only) and AM module internal shunt ratings.
(6) Use of external shunt disables internal IAM/AM shunt modules.
IMPORTANT
The Kinetix 6000 shunt module, catalog number 2094-BSP2, used in
combination with the 2094-AC09-M02-
x
IAM module, disables the
internal IAM module shunt resistor. This situation is unique to the
2094-AC09-M02-
x
IAM module. Shunt resistors internal to adjacent AM
modules are not disabled.
Содержание Allen-Bradley 2094-BC01-M01-S
Страница 4: ...4 Rockwell Automation Publication 2094 UM001D EN P May 2010 Summary of Changes Notes...
Страница 10: ...10 Rockwell Automation Publication 2094 UM001D EN P May 2010 Table of Contents Notes...
Страница 126: ...126 Rockwell Automation Publication 2094 UM001D EN P May 2010 Chapter 5 Connecting the Kinetix 6000 Drive System Notes...
Страница 228: ...228 Rockwell Automation Publication 2094 UM001D EN P May 2010 Appendix B Interconnect Diagrams Notes...
Страница 270: ...270 Rockwell Automation Publication 2094 UM001D EN P May 2010 Appendix F RBM Module Interconnect Diagrams Notes...
Страница 278: ...278 Rockwell Automation Publication 2094 UM001D EN P May 2010 Index Notes...
Страница 279: ......