Rockwell Automation Publication 2094-UM001D-EN-P - May 2010
185
Specifications and Dimensions
Appendix A
In this example, the continuous shunt power is 300 W. The 50 W resistor in the
IAM module is disabled when used in combination with the (2094-BSP2) shunt
module. This example is unique to the 2094-AC09-M02-
x
IAM module.
Figure 82 - 230V Shunt Power Example (2094-AC09-M02-
x
)
Use this table to understand the 460V system shunt specifications for the IAM
module internal shunt resistors, the 2094-BSP2 shunt module, and the Bulletin
1394 passive external shunt modules.
Table 103 - Shunt Module (460V) System Specifications
Kinetix 6000 (230V) Shunt Power Example
300 W Continuous Shunt Power
2094-BSP2 200 W Shunt Module
2094-AMP5-
x
AM Module, No Internal Shunt
2094-AM03-
x
AM Module, 50 W Internal Shunt
2094-AM03-
x
AM Module, 50 W Internal Shunt
2094-AC09-M02-
x
IAM Module, 50 W Internal Shunt
IAM
Module
2094-
Number of
Axis Modules
Qty
Shunt Module
Cat. No.
Shunt Module Specifications
External
Passive
Shunt Module
(1)
System
Continuous
Shunt Power
W
Resistance
Ω
Peak
Current
A
Peak
Power
kW
Continuous
Power
W
BC01-MP5-
x
0…7
N/A
(2)
–
–
–
–
N/A
(2)
50 plus
(3)
BC01-M01-
x
–
–
–
–
50 plus
(3)
BC02-M02-
x
–
–
–
–
50 plus
(3)
BC04-M03-
x
N/A N/A
–
–
–
–
N/A
200 plus
(4)
BC07-M05-
x
N/A N/A
–
–
–
–
N/A
BC
xx
-M
xx
-
x
1…6
2094-BSP2
28.75
28
22.5
200
N/A
(2)
200 plus
(5)
BC
xx
-M
xx
-
x
1…6
2094-BSP2
4
201.3
162
300
1394-SR9A
300
(6)
BC
xx
-M
xx
-
x
900
1394-SR9AF
900
(6)
BC
xx
-M
xx
-
x
1800
1394-SR36A
1800
(6)
BC
xx
-M
xx
-
x
3600
1394-SR36AF
3600
(6)
(1) Refer to External Shunt Module Specifications on
(2) Module not part of system configuration.
(3) 50 plus the sum of the AM module internal shunt ratings.
(4) 200 plus the sum of the AM module internal shunt ratings.
(5) 200 plus the sum of the IAM and AM module internal shunt ratings.
(6) Use of external shunt disables internal IAM/AM shunt modules.
Содержание Allen-Bradley 2094-BC01-M01-S
Страница 4: ...4 Rockwell Automation Publication 2094 UM001D EN P May 2010 Summary of Changes Notes...
Страница 10: ...10 Rockwell Automation Publication 2094 UM001D EN P May 2010 Table of Contents Notes...
Страница 126: ...126 Rockwell Automation Publication 2094 UM001D EN P May 2010 Chapter 5 Connecting the Kinetix 6000 Drive System Notes...
Страница 228: ...228 Rockwell Automation Publication 2094 UM001D EN P May 2010 Appendix B Interconnect Diagrams Notes...
Страница 270: ...270 Rockwell Automation Publication 2094 UM001D EN P May 2010 Appendix F RBM Module Interconnect Diagrams Notes...
Страница 278: ...278 Rockwell Automation Publication 2094 UM001D EN P May 2010 Index Notes...
Страница 279: ......