![Rockwell Automation Allen-Bradley 2094-BC01-M01-S Скачать руководство пользователя страница 58](http://html1.mh-extra.com/html/rockwell-automation/allen-bradley-2094-bc01-m01-s/allen-bradley-2094-bc01-m01-s_user-manual_1475821058.webp)
58
Rockwell Automation Publication 2094-UM001D-EN-P - May 2010
Chapter 4
Kinetix 6000 Connector Data
Motor Feedback Connector Pinout
Table 17 - Stegmann Hiperface (SRS/SRM)
Table 18 - TTL or Sine/Cosine with Index Pulse and Hall Commutation
Table 19 - Resolver Transmitter (transformation ratio = 0.25)
MF Pin
Description
Signal
MF Pin
Description
Signal
1
Sine differential input+
SIN+
9
Reserved
—
2
Sine differential input-
SIN-
10
Hiperface data channel
DATA-
3
Cosine differential input+
COS+
11
Motor thermal switch (normally closed)
(1)
TS
4
Cosine differential input-
COS-
12
Reserved
—
5
Hiperface data channel
DATA+
13
Reserved
—
6
Common
ECOM
14
Encoder power (+5V)
EPWR_5V
7
Encoder power (+9V)
EPWR_9V
(2)
15
Reserved
—
8
Reserved
—
(1) Not applicable unless motor has integrated thermal protection.
(2) Encoder power supply uses either 5V or 9V DC based on encoder/motor used.
MF Pin
Description
Signal
MF Pin
Description
Signal
1
AM+ / Sine differential input+
AM+ / SIN+
9
Reserved
—
2
AM- / Sine differential input-
AM- / SIN-
10
Index pulse-
IM-
3
BM+ / Cosine differential input+
BM+ / COS+
11
Motor thermal switch (normally closed)
(1)
TS
4
BM- / Cosine differential input-
BM- / COS-
12
Single-ended 5V hall effect commutation
S1
5
Index pulse+
IM+
13
Single-ended 5V hall effect commutation
S2
6
Common
ECOM
14
Encoder power (+5V)
EPWR_5V
7
Encoder power (+9V)
EPWR_9V
(2)
15
Reserved
—
8
Single-ended 5V hall effect commutation
S3
(1) Not applicable unless motor has integrated thermal protection.
(2) Encoder power supply uses either 5V or 9V DC based on encoder/motor used.
MF Pin
Description
Signal
MF Pin
Description
Signal
1
Sine differential input+
S2
9
Reserved
—
2
Sine differential input-
S4
10
Resolver excitation
R2
3
Cosine differential input+
S1
11
Motor thermal switch (normally closed)
(1) (2)
TS
4
Cosine differential input-
S3
12
Reserved
—
5
Resolver excitation
R1
13
Reserved
—
6
Common
ECOM
14
Reserved
—
7
Reserved
—
15
Reserved
—
8
Reserved
—
(1) Not applicable unless motor has integrated thermal protection.
(2) If using 1326AB (resolver-based) motors, use 2090-K6CK-D15MF Low-profile Connector Kits that connect the filtered thermal switch (pins 16 and 17) to MF-11 and MF-6.
Содержание Allen-Bradley 2094-BC01-M01-S
Страница 4: ...4 Rockwell Automation Publication 2094 UM001D EN P May 2010 Summary of Changes Notes...
Страница 10: ...10 Rockwell Automation Publication 2094 UM001D EN P May 2010 Table of Contents Notes...
Страница 126: ...126 Rockwell Automation Publication 2094 UM001D EN P May 2010 Chapter 5 Connecting the Kinetix 6000 Drive System Notes...
Страница 228: ...228 Rockwell Automation Publication 2094 UM001D EN P May 2010 Appendix B Interconnect Diagrams Notes...
Страница 270: ...270 Rockwell Automation Publication 2094 UM001D EN P May 2010 Appendix F RBM Module Interconnect Diagrams Notes...
Страница 278: ...278 Rockwell Automation Publication 2094 UM001D EN P May 2010 Index Notes...
Страница 279: ......