SECTION 4 — PROGRAMMING
SSC-500 Hydraulic Press Solid-State Control
Rockford Systems, LLC
26
Call: 1-800-922-7533
(Continued on next page.)
CLEAR STROKE
UP ARROW CONFIRM
Selects the Program Menu
Item CLEAR STROKE
ENTER
Display now reads...
MAIN
MENU
ENTER
OR
Press the UP arrow to
confirm the clear or enter
to abort
CLEAR STROKE
Select the
PROG
position on the Program/Run selector switch.
Press the
t
and
s
buttons on the keypad to scroll through the
program options. Press
ENTER
when the LCD displays
CLEAR STROKE
.
The display now reads:
UP ARROW CONFIRM
Press the
s
button on the keypad to clear the stroke counter, or press
the
ENTER
button to abort the clear and return to the main menu level.
The LCD again displays
CLEAR STROKE
.
Function
The 7-digit stroke counter is used to count strokes in the single or
automatic modes of operation only and can be displayed when the
Program/Run selector switch is in the
RUN
position.
Figure 4.4
CLEAR STROKE Programming Flowchart
QUICK REFERENCE TABLE - FACTORY SETTINGS AND VALID RANGES Table 4.1
Program Setting
Valid Entry Range
Factory Preset Setting
Clear Stroke
Clear/Abort
_
Clear batch
Clear/Abort
_
Batch Preset
0000000 - 9999999
0000000
Bottom dwell ms
0 - 3000 ms
0
Decompress timer
25 - 250 ms
Anti-Tiedown timer
100 - 7000 ms
250 ms
Single Return Mode
Off/On
Off
PSDI Timer
002 - 30 sec.
002 sec
Automatic single stroke mode
Off/On
Off
Auto single timer
005 - 120 sec. ms
005 sec.
User inputs
Input #1 - #4
Lube Flt/Off/E-Stop