Do not operate the press if the ground indicator light does not illuminate when the station is turned on.
Press Ground
The machine frame must always be firmly connected to ground in order to ensure that the control potential will never exceed 120 volts above ground.
Run a green grounding wire from the control box to some convenient location directly on the machine frame. Connect one end solidly to the frame
using a mounting bolt or other convenient means of attachment. Scrape any paint, rust, etc., from the area, to ensure an adequate ground connection.
Connect the other end to the “GND” terminal in the control box.
Note: All exposed metal components, which may be touched by personnel during normal operation or adjustment, must be firmly grounded to the
machine frame. The disconnect switch and motor starter should also be grounded if they are mounted separately.
Setup of Control System
The flowchart in Figure 4.1 outlines the order and method of setting up
and programming the SSC-500 control system on a hydraulic press
after installation. Refer to the LCD display on the control box or remote
operator station.
Power Up Control
Program User
Inputs
Program Standard
Settings
Ready for
Production
See Pages 29 - 30
Step
Completed
Step
See Pages 26 - 29
See Page 24
Program Additional
Settings
See Pages 30 - 33
Figure 4.1
Initial Setup Procedure Flowchart
Initial Setup Procedure
After completing the installation of the control box and control com-
ponents, the SSC-500 control system must be initially programmed in
order to get the machine up and running. To do this, please follow the
Initial Setup Procedure
below.
1.
Turn the main power disconnect switch for the control to the
ON position and start the main motor. The following information is
displayed on the LCD:
VERSION X.0
(X.0 = current keypad/display firmware version)
gg
SHC - X.0
gg
OPTION XX
(XX = current options available)
SAFEGRD IN PLACE
2.
After this information is displayed, press
ENTER
on the keypad if the
answer is
YES
to the
SAFEGRD IN PLACE
question.
3.
READY TO START (Press Motor Start)
The display message will indicate the position of the Program/Run
selector switch as follows:
If the selector switch is in the OFF position, the display message is
OFF
.
If the selector switch is in the RUN position, the display message is
SINGLE - STOP
If the selector switch is in the PROG position, the display message
is
CLEAR STROKE
.
4.
Proceed to the
Programming Overview
on page 25.
Figure 4.2 - Initial Information on Display