5.4.1.2
Connecting the drives to the MultiControl II quadro
Four drives can be connected for each control unit.
Only drives of the same version must be used for
all control units (exception: drive group manage-
ment
Personnel:
n
Assembly staff
Protective equipment:
n
Protective clothing
n
Safety shoes
Prerequisite:
n
The mains cable is disconnected from the voltage supply.
1.
If only one drive is connected to the control
unit, the cable must always be connected to
drive slot M1. Otherwise, the drive will not be
detected by the control unit.
Connect the cable of the first drive (Fig. 20/1) to drive slot
M1.
2.
If there are multiple drives, the following con-
figuration of drive slots is possible:
–
Two drives: M1 + M2 or M1 + M3
–
Three drives:
M1 + M2 + M3 or M1 + M3 + M4
–
Four drives: M1 + M2 + M3 + M4
If the configuration is different, the drives will
not be detected by the control unit.
If there are multiple drives, connect the cables of further
drives (Fig. 20/2) to the respective drive slots M2
-
M4 as per
the configuration options above.
ð
The drives have been connected.
If the 3 m long extension cable is used for the
drives, reduce the travel speed (parameter
11
Fig. 20: Connecting the drives
Assembly
Connecting the accessories > Connecting the drives
20.08.2021
Control unit RK MultiControl II duo/RK MultiControl II quadro
152