Switching resistor
R
switch
< 560 Ohms
Terminating resistor
1 k
£
R
terminating
£
10 k Ohms
5.4.4 Connecting the operator's stop input
Personnel:
n
Qualified electrician
Protective equipment:
n
Protective clothing
n
Safety shoes
Prerequisite:
n
The mains cable is disconnected from the voltage supply.
1.
Connect the BUS cable (Fig. 24/1) to the DATA interface on
the control unit.
2.
Connect the exposed wires of the BUS cable to the opera-
tor's stop input switch between 12 VDC and sensor input 4 in
accordance with the following table:
Pin
Wire
colour
Function
5
Pink
12 VDC
8
Blue
Sensor input 4
3.
Activate the "stop input" function
ð
The operator's stop input has been connected and acti-
vated.
If the stop input switch is actuated whilst a move-
ment is being performed, the drives stop as quickly
as possible.
If the stop input switch is deactivated
the drives can be moved again.
Connecting the stop input
Fig. 24: Connecting the BUS cable
(control unit)
Activating the stop input
Assembly
Connecting the accessories > Connecting the operator's stop input
20.08.2021
Control unit RK MultiControl II duo/RK MultiControl II quadro
157