Prerequisite:
n
The main menu for the hand switch is displayed
.
1.
Select the menu via
“Control”
®
“Commissioning”
®
“Start
the initialization”
2.
Press the (
) button if the number of connected control
units and drives is correct.
If the number is not correct, press the
(
) button.
3.
Press and hold the ( ) button until all drives have been
moved into the lower final position.
4.
Press and hold the ( ) button until all drives have been
moved into the upper final position.
ð
The initialization run has been completed.
The control unit is ready for operation.
If the upper final position cannot be
reached or an upward stroke limitation is
to be set, the initialization run can be
ended in any position.
To do so, press and hold the button for
approximately 5 s. The new position for
the upper final position of the drives has
been set.
Selecting a menu
Fig. 63: Selecting a menu
Carrying out an initialization run
Fig. 64: Carrying out an initialization
run
Operating the hand switch with 6 function buttons