Prerequisite:
n
The main menu for the hand switch is displayed
1.
Select the menu via
“Control”
®
“Parameter”
®
“Change
parameter”
ð
The
“Change parameter”
2.
Select the parameter as per the table of parameters
.
3.
ð
The parameter has been set.
No. Parameter
Default
(MLII)
Min.
Max.
1
Stroke display, input of the height for display when extended
1
1
9999
2
Basic height, input of the height for display when retracted: 0
-
%
0
0
9999
3
Unit, input of the unit for the display:
0
-
%; 1
-
cm; 2
-
mm; 3
-
inches
0
0
3
4
Safety edge: 0
-
deactivate; 1
-
activate
0
0
1
5
External stop input: 0
-
deactivate; 1
-
activate
0
0
1
Fig. 124: Selecting a menu
Changing parameters
Fig. 125: Selecting parameters
Fig. 126: Entering a value (example)
Table of parameters
Operating the hand switch with 6 function buttons
Control menu > Parameter menu
20.08.2021
Control unit RK MultiControl II duo/RK MultiControl II quadro