70
Upgrade and Maintenance Guide
Replacing SteelHead xx50
Components
Replacing Disk Drives
Replacing Disk Drives
The following sections describe how to replace disk drives in the xx50 appliances.
Note:
When you replace the disk drive, you must wear a grounded ESD antistatic strap to protect the hardware against
electrostatic discharge. Make sure that the strap makes skin contact prior to handling equipment.
If you have older hardware (for example, xx20 appliances), see the documentation set for RiOS v6.5.x or
earlier. To service appliance 50, 100, 200, and 300 disk drives, contact Riverbed Support at
https://support.riverbed.com.
Replacing Disk Drives in SteelHead 150, 250, and 550 Appliances
SteelHead 150, 250, and 550 appliances are equipped with a replaceable disk drive. The disk drive is not hot
swappable; you must first turn off the system and remove the power cord before you replace the disk
drives.
You must use approved disk drives. To order disk drives, contact your sales representative.
Caution:
SteelHead 150, 250, and 550 disk drives are not hot swappable. You must turn off the system and remove the
power cable before you replace the disk drive.
Caution:
When removing or replacing disk drives, be careful not to touch the adjacent power supply unit. Touching the
power supply unit can cause electric shock.
Caution:
Use caution when you remove or replace components; they can become hot to the touch.
To replace the disk drive
1.
Power down the SteelHead.
2.
Unplug the power cord from the AC circuit.
3.
Remove the SteelHead from its mounting rack, if necessary.
Содержание SteelCentral NetExpress 470
Страница 10: ...10 Upgrade and Maintenance Guide Preface Contacting Riverbed ...
Страница 40: ...40 Upgrade and Maintenance Guide Replacingxx70 Interceptor9600 andSteelFusionCore3500Components Replacing Fans ...
Страница 68: ...68 Upgrade and Maintenance Guide Replacing CX xx55 EX xx60 DX and SteelFusion Core Components Replacing Fans ...
Страница 90: ...90 Upgrade and Maintenance Guide Replacing SteelHead xx50 Components Replacing Fans ...