56
Upgrade and Maintenance Guide
Replacing CX xx55, EX xx60, DX, and SteelFusion Core
Components
R
eplacing Memory Modules
4.
Press the ejector tabs on the memory slots down and outward, and gently pull the memory module out
of the slot.
Figure 2-18. Accessing the Memory Modules
5.
If you are replacing memory, remove the existing memory module and replace it with the approved
memory module.
6.
Align the memory-module edge connector with the slot alignment keys and insert it into the slot.
The module slot has two alignment keys that allow you to install the module in only one direction.
Figure 2-19. Inserting and Securing the Memory Module in the DIMM Slot
7.
Press down on the memory module with your thumbs while pulling up on the ejectors with your index
fingers to lock the module into the slot.
8.
Ensure that all ejector tabs are in the upright locked position.
9.
Replace the chassis cover.
10.
Reconnect the power and power on the appliance.