Upgrade and Maintenance Guide
19
Replacing Disk Drives
R
eplacing xx70, Interceptor 9600, and SteelFusion Core 3500 Components
3.
Push down on the air duct to move it into place (letter C).
Figure 1-10. Installing the Air Duct
4.
For SteelHead CX, SteelHead Interceptor 9600, and SteelFusion Core 3500, plug in the SSD boot drive
cable.
Replacing Disk Drives
This section describes how to remove and replace disk drives in the SteelHead CX xx70, SteelCentral xx70,
SteelHead Interceptor 9600, and SteelFusion Core 3500 appliances.
This section includes the following procedures:
“Replacing Disk Drives in 1U Appliances with 3.5-inch Drives” on page 19
“Replacing Disk Drives in 2U Appliances with 2.5-inch Drives” on page 23
“Replacing Disk Drives in 2U Appliances with 3.5-inch Drives” on page 25
Note:
If you need to replace an appliance, you cannot move the disks to preserve your data. Each disk is encoded with
machine-level information and moving disks is not supported.
Replacing Disk Drives in 1U Appliances with 3.5-inch Drives
SteelHead CX3070, SteelCentral NetExpress 470, SteelCentral NetProfiler 4270DP, SteelCentral Flow
Gateway 2270, and SteelCentral NetShark 2170 appliances are equipped with replaceable, hot-swappable
3.5-inch hard-disk drives (HDD). SteelHead CX3070 appliances include HDDs and solid-state drives (SSD).
SteelCentral NetProfiler 4270DB/UI includes SSDs.
Содержание SteelCentral NetExpress 470
Страница 10: ...10 Upgrade and Maintenance Guide Preface Contacting Riverbed ...
Страница 40: ...40 Upgrade and Maintenance Guide Replacingxx70 Interceptor9600 andSteelFusionCore3500Components Replacing Fans ...
Страница 68: ...68 Upgrade and Maintenance Guide Replacing CX xx55 EX xx60 DX and SteelFusion Core Components Replacing Fans ...
Страница 90: ...90 Upgrade and Maintenance Guide Replacing SteelHead xx50 Components Replacing Fans ...