50
Upgrade and Maintenance Guide
Replacing CX xx55, EX xx60, DX, and SteelFusion Core
Components
Replacing Disk Drives
3.
Press the orange release button and pull the drive handle toward you.
Figure 2-12. Releasing the Disk Drive
4.
Slide the faulty disk drive out of the slot.
Make sure you remove the correct drive.
5.
Open the new disk-drive handle by pressing the orange release button.
6.
Slide in the new disk drive until it mates with the back connectors in the chassis.
The disk drive LED lights blue when connected.
7.
Press in the disk-drive handle to close.
The new disk drive runs through a self-test automatically. The disk drive automatically begins proper
operation with the other disk drives. You do not need to set up or configure the new disk drive.
Note:
It takes approximately 3 to 4 hours, depending on the system load, to rebuild a new disk drive. When the disk
drive has finished rebuilding, the system sends an email to the administrator user.
Replacing Disk Drives in 2U Appliances
The 2U CX5055, CX7055, DX8000, EX1360, and SteelFusion Core 3000 appliances are equipped with
replaceable, hot-swappable disk drives. You must use approved disk drives. To order disk drives, contact
Riverbed Support at https://support.riverbed.com.
Note:
When you replace disk drives, you must wear a grounded ESD antistatic strap to protect the hardware against
electrostatic discharge. Make sure that the strap makes skin contact prior to handling equipment.
Содержание SteelCentral NetExpress 470
Страница 10: ...10 Upgrade and Maintenance Guide Preface Contacting Riverbed ...
Страница 40: ...40 Upgrade and Maintenance Guide Replacingxx70 Interceptor9600 andSteelFusionCore3500Components Replacing Fans ...
Страница 68: ...68 Upgrade and Maintenance Guide Replacing CX xx55 EX xx60 DX and SteelFusion Core Components Replacing Fans ...
Страница 90: ...90 Upgrade and Maintenance Guide Replacing SteelHead xx50 Components Replacing Fans ...