266
MediorNet User Manual 2.00.0
Sync. Priority
Master
Highest priority. Frame becomes sync master when error free sync signal is
detected on sync input and no other Frame has same configuration.
Secondary Master
Second priority level. Frame becomes sync master when error free sync signal is
detected on sync input and no other Frame has same configuration and higher
or same priority.
Tertiary Master
Third priority level. Frame becomes sync master when error free sync signal is
detected on sync input and no other Frame has same configuration and higher
or same priority.
none
No priority is set to this Frame. Frame can only become sync master in
MediorNet when no other Frame has higher priority settings.
Sync. In
Shows which type of sync signal is connected on
Sync In.
Sync. Out
Selects which
sync signal
type should be generated on the output. It's possible to generate sync signals
of different types on different Frames.
VITC Out
Enable or disable of embedding the timecode in the Sync-signal.
Leading Sync. Out
The Sync signal is generated 500µs before the MediorNet wide sync signal.
TC Source
The MediorNet acts as a timecode generator if the sync master does not detect a VITC on the
Sync In
port, or if the
Sync In is lost. In this case the TC Mode must be set.
When
Sync Out ports are configured for Blackburst PAL the VITC is in lines 19 and 21, when configured for
Blackburst NTSC the VITC is in lines 14 and 16.
Reports the TC format of the currently connected sync in signal, left blank if there is no sync in or no
valid TC. Possible Values:
LTC
external Longitudinal (Linear) Timecode
VITC
external Vertical Interval Timecode
internal
internal Timecode
TC Mode
Only modifiable on the sync master if no external TC is detected, otherwise the
TC Mode is fixed to the
Sync In TC Mode. Used to select how the timecode is counted. The same values as in the TC Source
column apply.
Button
Restore Sync. Priorities
The original Sync-Master is switched back after pressing the button (f.i. if a Secondary Master was used).
A short signal interruption may occur by changing the Sync-Master.
USO
RESTRITO
Содержание MediorNet
Страница 1: ...MediorNet User Manual USO RESTRITO ...
Страница 11: ...11 MediorNet User Manual 2 00 0 Figure 2 overview of topology USO RESTRITO ...
Страница 92: ...92 MediorNet User Manual 2 00 0 Figure 136 Output Channel configuration USO RESTRITO ...
Страница 308: ...308 MediorNet User Manual 2 00 0 Notes USO RESTRITO ...
Страница 309: ...309 MediorNet User Manual 2 00 0 Notes USO RESTRITO ...
Страница 310: ...www riedel net Riedel Communications GmbH Co KG Uellendahler Str 353 42109 Wuppertal Germany USO RESTRITO ...