20 June 2005
PHOTOCONDUCTOR UNIT (PCU)
3-37
Replacement
Adjustment
3.11.7 ID SENSOR
Remove:
•
Remove the PCU (
3.11.1)
•
Fusing unit (
3.15)
•
Development unit (
3.12.1)
1. Remove the PCU rail [A] (
x2,
x1)
2. Remove the ID sensor bracket [B] (
x1,
x1)
3. Remove the ID sensor [C] (
x1)
4. Do SP3-001-2 to initialize the ID sensor.
B195R941.WMF
[B]
[C]
[A]