SERVICE PROGRAM MODE TABLES
5-117
Service
Tables
5.2.4 TEST PATTERN PRINTING: SP2-902
NOTE:
Always print a test pattern to confirm correct operation of the machine.
1. Enter the SP mode and select SP2-902.
2. Press
or
.
•
IPU Test Print
•
Test Pattern
3. Enter the number for the test pattern that you want to print and press
. (See
the tables below.)
4. When you are prompted to confirm your selection, press Yes. This selects the
test pattern for printing.
5. Press Copy Window to open the copy window and then select the settings for
the test print (paper size, etc.)
6. Press Start
twice. (Ignore the “Place Original” messages) to start the test
print.
7. Press SP Mode (highlighted) to return to the SP mode display.
Test Pattern Table (SP2-902-2: IPU Test Print)
No.
Test Pattern
No.
Test Pattern
0
None
8
Grayscale (Horizontal)
1
Vertical Line (1-dot)
9
Grayscale (Vertical)
2
Horizontal Line (1-dot)
10
Cross Pattern
3
Vertical Line (2-dot)
11
Cross Shape
4
Horizontal Line (2-dot)
12
Argyle Pattern
5
Alternating Dot Pattern
13
Cross Pattern (256)
6
Grid Pattern (1-dot)
14
Cross Pattern (64)
7 Vertical
Strips