SERVICE PROGRAM MODE TABLES
20 June 2005
5-58
5846*
UCS Setting
Machine ID (for Delivery Server)
5846 1
Displays the unique device ID in use by the delivery server directory. The value is
only displayed and cannot be changed.
This ID is created from the NIC MAC or IEEE 1394 EUI.
The ID is displayed as either 6-byle or 8-byte binary.
6-byte
%02X.%02X.%02X.%02X.%02X.%02X
8-byte
%02X.%02X.%02X.%02X.%02X.%02X.%02X.%02X
Machine ID Clear (Delivery Server)
5846 2
Clears the unique ID of the device used as the name in the file transfer directory.
Execute this SP if the connection of the device to the delivery server is unstable. After
clearing the ID, the ID will be established again automatically by cycling the machine
off and on.
Maximum Entries
5846 3
Changes the maximum number of entries that UCS can handle.
[2000~50000/1]
If a value smaller than the present value is set, the UCS managed data is cleared,
and the data (excluding user code information) is displayed.
Delivery Server Retry Timer
5846 6
Sets the interval for retry attempts when the delivery server fails to acquire the
delivery server address book.
[0~255/1 s]
0: No retries
Delivery Server Retry Times
5846 7
Sets the number of retry attempts when the delivery server fails to acquire the
delivery server address book.
[0~255/1]
Delivery Server Maximum Entries
5846 8
Lets you set the maximum number of account entries and information about the users
of the delivery server controlled by UCS.
[20000~50000/1]
LDAP Search Timeout
5846 10
Sets the length of the time-out for the search of the LDAP server.
[1~255/1]