Text Mode
Adjust the image for the Text mode with the four master settings within their
allowed ranges (for ranges see Section “5. Service Tables”. To fine adjust a master
setting set it to “0” then perform the adjustments listed below.
SP4904 020 = 0
Text (General) Quality 25-64%
SP4903 020
Main Scan Filter Level: Text 25%-64%
SP4903 021
Sub Scan Filter Level: Text 25%-64%
SP4903 022
Main Scan Filter Strength: Text 25%-64%
SP4903 023
Sub Scan Filter Strength: Text 25%-64%
SP4904 021 = 0
Text (General) Quality 65-154%
SP4903 024
Main Scan Filter Level: Text 65%-154%
SP4903 025
Sub Scan Filter Level: Text 65%-154%
SP4903 026
Main Scan Filter Strength: Text 65%-154%
SP4903 027
Sub Scan Filter Strength: Text 65%-154%
SP4904 022 = 0
Text (General) Quality 155-256%
SP4903 028
Main Scan Filter Level: Text 155%-256%
SP4903 029
Sub Scan Filter Level: Text 155%-256%
SP4903 030
Main Scan Filter Strength: Text 155%-256%
SP4903 031
Sub Scan Filter Strength: Text 155%-256%
SP4904 023 = 0
Text (General) Quality 257%-400%
SP4903 032
Main Scan Filter Level: Text 257%-400%
SP4903 033
Sub Scan Filter Level: Text 257%-400%
SP4903 034
Main Scan Filter Strength: Text 257%-400%
SP4903 035
Sub Scan Filter Strength: Text 257%-400%