20 June 2005
ENERGY SAVER MODES
6-107
Detailed
Descriptions
Off Mode
The 5V supply also turns off. However, +5VE (+5V for energy saver
mode) is still activated. When the machine detects a ringing signal, off-hook signal,
or receives a print job, the machine returns to the Off Stand-by mode and the
5V and +24V supplies are activated.
Returning to stand-by mode
The machine returns to stand-by mode when the operation switch is pressed. The
recovery time is about 10 s (B003/B006) or 15 s for the (B004/B007).
Mode
Operation
Switch
Energy
Saver
Mode
Fusing Lamp
+24V
System
+5V
Note
Off Stand-by
Off
Off
Off
(On when printing)
On On
Off Off
Off Off Off
Off
+5VE is