DUPLEX UNIT
20 June 2005
6-82
6.13.4 DUPLEX UNIT FEED IN AND EXIT MECHANISM
Feed-in
The inverter gate solenoid [A] stays off and the inverter rollers [B] rotate clockwise.
A sheet of paper is sent to the inverter section [C].
NOTE:
The cover guide has been eliminated in order to accommodate paper sizes
longer than A4/LT in the reverse feed path which has been lengthened in
the design of this machine.
Inversion and Exit
The inverter gate solenoid turns on and the inverter motor turns on in reverse
shortly after the trailing edge of the paper passes through the entrance sensor [D].
As a result, the inverter gate [E] is opened and the inverter roller rotates
counterclockwise. The paper is sent to the copier through the upper and lower
transport rollers [F, G].
B195D965.WMF
B195D967.WMF
[A]
[D]
[B]
[E]
[F]
[C]
[G]