5-4
CW-80 Checkweigher Installation/Service Manual
PTT/SET Mode
Installer-Configured Graduation (dd) Values
OU SET Mode
In OVER UNDER SET mode, the lower
(Un 1) and upper (Ov 1) limits of the
ACCEPT band are entered digitally
through the keyboard by the operator.
The operator presses the UNDER key,
then enters the Un 1 value. He then
presses the OVER key and enters the Ov 1
value. Weights falling between these limits
will be in the ACCEPT range.
All other tolerance values (Un 1-2, Un 2,
Ov 1-2, Ov 2) controlling the Under/
Accept/Over LED display lights are pre-
set by the installer at SETUP time.
PUSH TO TOLERANCE/SET mode
combines both methods (acquired and
digitally set) for establishing the ACCEPT
band. The Un 1 value is first acquired as
in PTT mode on previous page. This
acquired value can then be altered by
pressing UNDER again and digitally
modifying the value. Ov 1 operates in a
similar fashion.
All other tolerance values (Un 1-2, Un 2,
Ov 1-2, Ov 2) controlling the Under/
Accept/Over LED display lights are pre-
set by the installer at SETUP time.
UNDER
OVER
ACCEPT
SLIGHTLY
SLIGHTLY
MODERATELY
GREATLY
GREATLY
UNDER
OVER
Un 1
Ov 1
Ov 1-2
Ov 2
Un 1-2
Un 2
Operator Numeric Entry Required
Installer-Configured Graduation (dd) Values
UNDER
OVER
ACCEPT
SLIGHTLY
SLIGHTLY
MODERATELY
GREATLY
GREATLY
UNDER
OVER
Un 1
Ov 1
Ov 1-2
Ov 2
Un 1-2
Un 2
Checkweigher-Acquired or Operator-Entered Weight Values