5-2
CW-80 Checkweigher Installation/Service Manual
UNDER
OVER
ACCEPT
SLIGHTLY
SLIGHTLY
MODERATELY
GREATLY
GREATLY
UNDER
OVER
Un 1
Ov 1
Ov 1-2
Ov 2
Un 1-2
Un 2
Overview of Operating Modes
The following pages use graphics to summarize how each operating mode
functions. This page provides a key (using the two figures below) for
reading those graphics on the following pages. Note that all graphics assume
you are using a scale with 30 lb capacity, set up for 3,000 grads (20 x .01), a
Count By of 1, and 2 decimal places.
All settings above the UNDER/
ACCEPT/OVER display bar are
made by the operator in normal
weighing mode, and are in the
default unit of weight.
All settings below the UNDER/
ACCEPT/OVER display bar are
made by the installer in
Configuration mode, and are in
graduations.
NOTE:
Grad settings are successively
cumulative to Ov 1 and Un 1
settings. For instance, the LED
light furthest left (Un 2) comes
on when the cumulative grad
settings for Un 1 and Un 1-2
have been surpassed.
UNDER
OVER
ACCEPT
SLIGHTLY
SLIGHTLY
MODERATELY
GREATLY
GREATLY
UNDER
OVER
Un 1
Ov 1
Ov 1-2
Ov 2
Un 1-2
Un 2
A scale and container icon indicates the operator has set
Ov 1 or Un 1 by placing an actual weight on the scale,
then pushing either the OVER or UNDER button.
An OVER or UNDER button icon with numbers
below indicates Un 1 or Ov 1 weight values
digitally entered using the keypad .