Radio Frequency Systems
BD210WLP Series Air Dryer User’s Guide
Page 77 of 101
100518832 – Rev. B
10.2 Six Month Maintenance
MODEL:
LOCATION NAME:
SERIAL NUMBER:
ADDRESS:
DATE INSTALLED:
Maintenance Interval (Months)
Procedure
Section
6
12
18
24
30
Measure & Record
Compressor Amp Draw
Measure & Record Incoming Voltage
(must be 110 - 125 VAC for BD210WLP models and
must be 208 - 253 VAC for BD212WLP models)
Test High & Low Outlet Pressure Alarms
Set System Pressure (50 PSI (344.7 KPa))
Set Outlet Pressure
Test Consistent Heatless Dryer Cycling
Test Fan
Test Compressor ON/OFF Cycling
Test High Compressor Last Run Time Alarm
Test Humidity Alarm & System Shutdown
Test Air Fittings for Leaks
Visually Inspect Inside & Outside of Unit for Loose
Wiring or Hardware
Maintenance Performed by:
Date of Maintenance:
NOTE:
COPY OR PRINT THIS PAGE AND KEEP IT WITH THE AIR DRYER