100518832 – Rev. B
control board (section
11.1 )
System is in Shutdown
state
On the Display Panel,
verify that the system is
in
SHUTDOWN
state
Press the
RESET
Button
Compressor stalled
Measure compressor
voltage
(section 9.3 ) & Verify
System Pressure
(section 8.9 )
Adjust incoming
voltage / system
pressure if necessary
and Power the air Dryer
OFF
for 15+ seconds.
Power the air Dryer
ON
.
13.16 Compressor Won’t Build Pressure
Possible Cause
Check
Corrective Action
Low System Pressure
Verify System Pressure
(section 8.9 )
Adjust System Pressure
to 50 PSI (344.7 KPa) ±
2 PSI (13.8 KPa).
(section 8.9 )
Leak in air system
Check all hoses and
fittings between
compressor and Air
Tank for air leaks
(section 9.13 )
Connect, tighten, or
replace leaking
component
Compressor Piston
Leaking
Check the pressure of
the outlet air coming
from the compressor to
the pressure setting on
the capacity control
valve
Replace the compressor
piston seal included in
the Annual
maintenance kit
13.17 Compressor Excessive AMP Draw
Possible Cause
Check
Corrective Action
Restriction in air line
Remove Discharge
Hose from compressor
(hose to the heatless
Dryer)
If measurement is
below the
recommended amps,
trace hoses from
compressor to Capacity
Содержание BD210WLP Series