Radio Frequency Systems
BD210WLP Series Air Dryer User’s Guide
Page 72 of 101
100518832 – Rev. B
9.12.4
Turn Outlet Pressure
Regulator knob clockwise
until Outlet Pressure (
OUTP
)
reading rises to the reading
recorded in step 9.12.1
9.12.5
Tighten the retaining nut to
lock the setting in place.
9.12.6
Press the
RESET
Button
.
If you are unable to create a Low Outlet
Pressure Alarm as described, see section
13.9 for troubleshooting information.
9.13 Testing Air Fittings & Hoses for Leaks
NOTE:
This is a general procedure that can be applied to any fitting or hose that
has air pressure in it.
DO NOT SOAP TEST THE HUMIDITY SENSOR
FITTING. DAMAGE TO THE SENSOR MAY OCCUR.
With Compressor NOT running:
9.13.1
Listen for any ‘hissing’ sounds which may indicate a fitting or hose air
leak.
Содержание BD210WLP Series
Страница 2: ......